7 Replacing COM3 Port
5 Replacing COM3 Port
To replace the COM3 port:
1. Remove the power adapter, pedestal and side cover. For more information see, section
Error! Reference source not found.’ on page 3
2. Remove the COM3 port screws at the back of the thin client using the nut driver.
Figure 9: COM3 Port Screws
3. Remove the glue by applying isopropyl alcohol, pull the glue out using the nose pliers.
Figure 10: COM3 Port Cable Connecter